Sponsored Links
-->

Sunday, May 27, 2018

Amniocentesis. Ultrasound Control Stock Illustration ...
src: thumbs.dreamstime.com

Amniocentesis (also referred to as amniotic fluid test or AFT) is a medical procedure used in prenatal diagnosis of chromosomal abnormalities and fetal infections, and also for sex determination, in which a small amount of amniotic fluid, which contains fetal tissues, is sampled from the amniotic sac surrounding a developing fetus, and then the fetal DNA is examined for genetic abnormalities. The most common reason to have an "amnio" is to determine whether a baby has certain genetic disorders or a chromosomal abnormality, such as Down syndrome. Amniocentesis (or another procedure, called chorionic villus sampling (CVS)) can diagnose these problems in the womb. Amniocentesis is performed when a woman is between 14 and 16 weeks gestation. Women who choose to have this test are primarily those at increased risk for genetic and chromosomal problems, in part because the test is invasive and carries a small risk of miscarriage. This process can be used for prenatal sex discernment and hence this procedure has legal restrictions in some countries.

Several researchers worked on the development of amniocentesis for fetal sex determination in the 1950s.

Between 1959 - 1967 Robert Lisle Gadd developed the new technique of amniocentesis for clinical assessment of fetal wellbeing in utero. He presented his results at the William Blair-Bell Memorial Lecture at the RCOG in London in 1965 and was awarded an MD from the University of Manchester for this work. He also described amniocentesis techniques, as well as other details about amniotic fluid in the chapter 'The Liquor Amnii' in the 1970 and 1977 editions of Scientific Foundations of Obstetrics and Gynaecology.

Up to mid 1970s amniocentesis procedures were done 'blind'. Doctors Jens Bang and Allen Northeved from Denmark were the first to report amniocentesis done with the guide of an ultrasound in 1972. Chorionic Villus Sampling (CVS) was first performed by Italian biologist Giuseppe Simoni in 1983. Now real-time ultrasound is used during all invasive procedures because it provides for the safety of the fetus and accuracy of results.


Video Amniocentesis



Procedure

Before the start of the procedure, a local anesthetic can be given to the mother in order to relieve the pain felt during the insertion of the needle used to withdraw the fluid. After the local anesthetic is in effect, a needle is usually inserted through the mother's abdominal wall, then through the wall of the uterus, and finally into the amniotic sac. With the aid of ultrasound-guidance, a physician punctures the sac in an area away from the fetus and extracts approximately 20ml of amniotic fluid. If used for prenatal genetic diagnosis, fetal cells are separated from the extracted sample. The cells are grown in a culture medium, then fixed and stained. Under a microscope the chromosomes are examined for abnormalities. The most common abnormalities detected are Down syndrome (trisomy 21), Edwards syndrome (trisomy 18), and Turner syndrome (monosomy X). In regard to the fetus, the puncture seals and the amniotic sac replenishes the liquid over the next 24-48 hours.


Maps Amniocentesis



Indications and results

Genetic diagnosis

Early in pregnancy, amniocentesis is used for diagnosis of chromosomal and other fetal problems such as:

  • Down syndrome (trisomy 21)
  • Trisomy 13
  • Trisomy 18
  • Fragile X
  • Rare, inherited metabolic disorders
  • Neural tube defects (anencephaly and spina bifida) by alpha-fetoprotein levels.

Lung maturity

Amniocentesis can predict fetal lung maturity, which is inversely correlated to the risk of infant respiratory distress syndrome. In pregnancies of greater than 30 weeks, the fetal lung maturity may be tested by sampling the amount of surfactant in the amniotic fluid. Several tests are available that correlate with the production of surfactant. These include the lecithin-sphingomyelin ratio ("L/S ratio"), the presence of phosphatidylglycerol (PG), and more recently, the surfactant/albumin (S/A) ratio. For the L/S ratio, if the result is less than 2:1, the fetal lungs may be surfactant deficient. The presence of PG usually indicates fetal lung maturity. For the S/A ratio, the result is given as mg of surfactant per gm of protein. An S/A ratio <35 indicates immature lungs, between 35-55 is indeterminate, and >55 indicates mature surfactant production(correlates with an L/S ratio of 2.2 or greater).

Other

Amniocentesis can also be used to detect problems such as:

  • Infection, in which amniocentesis can detect a decreased glucose level, a Gram stain showing bacteria or an abnormal differential count of white blood cells.
  • Rh incompatibility
  • Decompression of polyhydramnios

An emerging indication for amniocentesis is in the management of preterm rupture of membranes where measurement of certain amniotic fluid inflammatory markers may be helpful. If amniotic fluid IL-6, a marker of inflammation, is elevated, the fetus is at high risk and delivery should be considered.


Amniocentesis vs Chorionic Villus Sampling - YouTube
src: i.ytimg.com


Risks and drawbacks

Amniocentesis is performed between the 15th and 20th week of pregnancy; performing this test earlier may result in fetal injury. The term "early amniocentesis" is sometimes used to describe use of the process between weeks 11 and 13.

Complications of amniocentesis include preterm labor and delivery, respiratory distress, postural deformities, chorioamnionitis, fetal trauma and alloimmunisation of the mother (rhesus disease). Studies from the 1970s originally estimated the risk of amniocentesis-related miscarriage at around 1 in 200 (0.5%). Three more recent studies from 2000-2006 estimated the procedure-related pregnancy loss at 0.6-0.86%. A more recent study (2006) has indicated this may actually be much lower, perhaps as low as 1 in 1,600 (0.06%). Unlike the previous studies, the number in this study only reflects the loss that resulted from amniocentesis complications and excluded the cases when parents decided for an abortion following the test results. In contrast to amniocentesis, the risk of miscarriage from chorionic villus sampling (CVS) is believed to be approximately 1 in 100, although CVS may be done up to four weeks earlier, and may be preferable if the possibility of genetic defects is thought to be higher.

Amniotic fluid embolism has been described as a possible risk.

Social implications

The prenatal diagnosis of chromosomal abnormalities can have social drawbacks as technology changes the way people think about disability and kinship. There is potential for intensification of attitudes of discrimination towards those with a disability, whose births could have been prevented through technology such as amniocentesis. In one sense, amniocentesis offers a window of control and in another, an anxiety-provoking responsibility to make rational decisions about complex, emotional and culturally contingent issues.


Amniocentesis - Indications - Complications - Procedure - TeachMeObGyn
src: cdn1.teachmeseries.com


Amniocentesis and stem cells

Recent studies have discovered that amniotic fluid can be a rich source of multipotent mesenchymal, hematopoietic, neural, epithelial, and endothelial stem cells.

A potential benefit of using amniotic stem cells over those obtained from embryos is that they side-step ethical concerns among pro-life activists by obtaining pluripotent lines of undifferentiated cells without harm to a fetus or destruction of an embryo. These stem cells would also, if used to treat the same individual they came from, sidestep the donor/recipient issue which has so far stymied all attempts to use donor-derived stem cells in therapies.

Artificial heart valves, working tracheas, as well as muscle, fat, bone, heart, neural and liver cells have all been engineered through use of amniotic stem cells. Tissues obtained from amniotic cell lines show promise for patients suffering from congenital diseases/malformations of the heart, liver, lungs, kidneys, and cerebral tissue.

The first amniotic stem cells bank in the US is active in Boston, Massachusetts.


Science Source - Amniocentesis, Illustration
src: www.sciencesource.com


See also

  • Chorionic villus sampling
  • Percutaneous umbilical cord blood sampling
  • Prenatal diagnosis
  • Amniotic stem cells
  • Amniotic fluid

Amniocentesis - YouTube
src: i.ytimg.com


References


Ultrasound scan amniocentesis Stock Photo: 1684816 - Alamy
src: c8.alamy.com


External links

  • Amniodex is an interactive decision support intervention designed for women faced with the decision of whether to undergo amniocentesis.
  • The Amniocentesis Report A Decision Guide for Expectant Parents and Health Care Professionals.
  • http://www.sutherlandhealth.com/companies/condomania/product-range/vision/amniotic-leak-detector

Source of article : Wikipedia